QDCE builds chute systems in Qingdao and ships them to residential towers, hotels,hospitals and construction sites. We are a manufacturer, not a trading company: the doors, duct sections, brackets and discharge gates that leave our workshop were cut, formed, welded and finished in it.
What We Make
Five product lines, all fabricated in-house.
Trash chutes for residential and commercial buildings, in 24", 30" or 36" (600, 750 or 900 mm) bore.
Linen chutes for hotels, hospitals and residences, built to the same fabrication standard but sized for the bundle rather than the bag.
Construction chutes in HDPE, section by section, for taking debris off a floor while the building is still going up.
Compactors for the collection room, matched to the chute's discharge volume.
Components — intake doors, hoppers, interlock panels, vents, discharge gates and wall brackets, so a replacement part does not have to come from whoever built the shaft.
How a Chute Gets Built
A chute is a tall, thin stainless box that has to stay straight over a full building height. Almost everything that goes wrong in one starts in fabrication, not on site.
Sheet is cut to the developed size of each section, then formed into the 1200 mm and 600 mm lengths that make up a riser. Sections are TIG welded, and every one is checked for straightness after welding — weld shrinkage pulls a section out of line, and a riser that is out of line by the tenth floor rubs at the twentieth. The inside face is dressed smooth at the joint, because a step of a millimetre is enough for a bag to catch on over fifty floors. Sections are trial-assembled before finishing, so the run is proven straight in the workshop rather than on a scaffold.
Duct sheet runs 1.2, 1.5, 2.0 or 3.0 mm depending on bore and drop. Door faces are 16 gauge (1.6 mm) SS304 on both sides. We also fabricate in galvanized steel and aluminium where a project calls for it.
What We Are Certified For
Fabrication is ISO 9001 certified.
Our intake doors carry UL 10B certification with a 1.5-hour rating — the door, not the whole assembly, which is how the listing works and why a replaced door has to be the same listed model. The discharge gate at the base is held by a UL-listed fusible link that releases at 74°C (165°F). Risers are designed to NFPA 82 requirements where applicable; NFPA does not certify a complete chute system, and we will not claim it does.
Where Our Work Goes
Residential towers, hotels and serviced residences, hospitals and clinics, office and mixed-use buildings, and construction sites, in 54 countries.
We do not publish client names. Contractors and developers buy from us on the understanding that their project stays theirs, so what we show is scope, country and year — never the building's address.
How We Work With You
Send the floor count, shaft size and drawings. You get layout recommendations and shop drawings back with the price, inside 12 hours.
Drawings are issued before fabrication, and they are what the workshop builds to. If the shaft on site has moved since the architect's drawing, we would rather redraw than ship a section that has to be cut on the landing.
Intake doors, closers, latches and gate hardware are held for ten years after a system ships. A door that fails in year seven should be a part number, not a redesign.
Installation is by your contractor. We supply the anchor details, the section numbering and the assembly sequence, and we answer the phone while it goes up.
Send Us the Floor Count
Whether it is one riser in a new tower or replacement doors on a system that has been
running for twenty years, the starting information is the same: how many floors, what
the shaft measures, and what the building is used for.