Hopper

banner
Laundry Chute2
2D998250-AAA3-4BA9-B2B7-371E06DCBA8F_AI看图
Trash Bin Compactor system5
Laundry Chute2
2D998250-AAA3-4BA9-B2B7-371E06DCBA8F_AI看图
Trash Bin Compactor system5
Garbage Chute

Hopper

Chute Duct

A garbage chutes system is a long vertical space passing by each floor in a building. It consist of door on each floor where residents can through the waste into the chute. This door is usually contained in a small room on each floor. Garbage placed in the chute drops to a compactor or dumpster at the bottom.

Garbage chutes are mechanisms that connect trash from each floor of a building, select floors of each building via a chute, allowing all trash to collectively compile in a singular location. Garbage chutes are essential to apartment buildings, and make for an effective way to dispose of trash.

Our Chutes are fully factory fabricated with all joints welded or lock seamed. There is one slip joint per floor. All chutes have a flush interior and are assembled without bolts, rivets or clips protruding into the chute opening. Chutes are equipped with chute support clips pre-positioned at the factory to insure proper chute alignment. The adjustable intake door and frame are securely fastened to the intake throat. If required, off-sets will be reinforced and supported in impact areas.

Material

Our chutes are constructed of 16 gauge standard stainless steel, SS316, SS304 or any material customized

Sizes

Chutes are available in 36″, 30″, and 24″ diameters or any size customized.

The standard chute size is 24″ per NFPA recommendations.

(0) Reviews

Product Details

  • We proudly makes all of our own trash chute, garbage chute, linen chute and laundry chute, pneumatic waste chute, construction chute, Compactor and other products. We are always in the position to supply our overseas customers with high quality, steady quantity, and delivery on time and at the competitive prices.

  • Garbage chute and linen chute are designed to provide a clean and efficient method of removing waste and soiled linens from upper floors to a centrally located discharge area on a lower floor.It is a very convenient, simple and low cost method of controlling and disposing of refuse and linen in multi-storey buildings.

  • Our chutes meet the most stringent requirements of fire fighting ,environmental health and safety.

Product Features

Ventilation System

 To be shaped from Vent Duct, Exhaust Fan, Weather Cowl, Bird &Insect Screen, and Flashing cover.

A full diameter vent is required by NFPA, which can exhaust the bad odor into the atmosphere. QDCE recommends a minimum of 20ACH in the chute system.


Brush Cleaning System

A cylindrical nylon brushes can move up and down inside the chute, to scrape and clean the chute internal wall ,meanwhile, sanitizing unit and the flushing head system begin to work. Stiff nylon brushes can be replaceable.

Brush cleaning system should be operated every three or six months.

This system can be controlled by control panel in the bottom collection room.


Sanitizing and disinfecting units

Located on the topmost of the chute, and it should be controlled by electonic solenoid valve.  After the maintainer push the botton ‘D&S’ in the bottom collection room, the solenoid valve opens and the disinfectant enters the water supply. The spiral nozzle provides a cone water shap that covers the internal wall of chute.Meanwhile, All intake doors should be locked during cleaning process.

After a specified time, water supply will stop automatically and release the door locks.


Straight Chute Section & Intake Chute Section

Chute Duct section is from the bottom collection room to the top floor. The duct section are continuously TIG welded and polished, which ensures watertight system without any bolts, rivets or other protrusion inside the chute.


Supporting Frame

Hot dip galvanized, which can be Rust Protection


Sound Attenuation System

Sound dampening coating, Rubber isolator pad, and Rubber washer, etc.  which Can allow trash’s convey in a quiet.


Intake Door(1.5 Hours UL Fire-Rated Certificated)

Pass UL 1.5 hr fire-rated test, and any size can be customerized per customer’s request.


Interlocking System

Two type of interlocking system: safe-type and secure-type. will allow only one user at a time to open the door, and show busy indicator on all other floors when operation is going at another floor and service time and fire-warning time.


Recycle chute system

Choosing between Wet garbage, Dry garbage chute and Recycled Item by pushing button of intake door, to transfer 2 or 3 types of waste into their respective trolley.


LCD Main Control Panel

It controls D&S Unit, Cleaning System,  Fan, Maintenance, Emergency,Brushing System. Also LCD can display all the status of the door and the other functions. Integration with BMS.


Sprinklers & Flushing System

Fire Control System


Offset Chute(Elbow Chute)

Double (two bends) offset, made of full 3.0mm thicknes SS material.


Discharge Door(Fire Cutoff Door) or Electrical Automatic Cutoff Door

Installed on the bottom of the chute, and  it can cut off and close the chute once fire happened in the garbage collection room (with a fusible link melts at 74℃ fusible link(UL Label)).


Compactor

Bi-Sorter/Tri-sorter(can be customized per your site)

To transfer 2 or 3 types of waste into their respective trolley.


Other Parts

Within the overall design of chutes have greatly increased their usage throughout the world.

Specifications & Technology

Item

Hopper

Condition

New

None

Hotels, Food & Beverage Factory, Restaurant, Construction works

Place of Origin

China,Shandong

Brand Name

QDCE

Type

Refuse Collector

Warranty

1 Year

Material

All stainless steel

Machinery Test Report

Provided

Video outgoing-inspection

Provided

Marketing Type

Ordinary Product

Warranty of core components

1 Year

Core Components

PLC, Pump, Engine

Weight (KG)

1000kg


Automated Cleaning & Odor Control

The Hygienic Advantage: Self-Cleaning Stainless Steel Chutes

  • Brush Cleaning System:

    A motorized, cylindrical nylon brush travels the entire length of the chute, scraping debris from the interior walls. Optimal operation is every three to six months.

  • Sanitizing & Disinfecting Unit (D&S):

    Located at the top, a spiral nozzle delivers a cone-shaped spray of disinfectant, ensuring 360° internal coverage.

  • Forced Ventilation:

    A full-diameter vent with an Exhaust Fan. Recommended minimum 20 ACH (Air Changes per Hour) for effective odor control.

Automated Cleaning & Odor Control
Noise Reduction & Construction

Engineered for Quiet Operation and Longevity

  • Noise Attenuation:

    Features a specialized Sound Dampening Coating on the exterior, Rubber Isolator Pads at floor connections, and Rubber Washers.

  • Chute Duct Material:

    16 Gauge (min.) Stainless Steel (SS304/SS316)

  • Watertight Seams:

    Sections are continuously TIG Welded and Polished to ensure a smooth, watertight interior without rivets or bolts.

Noise Reduction & Construction

Leave a Message

lf you have any questions or needs about the product, please fill in the following form and we wll contact you as soon as possible.

Customer Reviews

Write A Review

  • Your Rating:

FRESH NEWS

Latest News & Articles

GET IN TOUCH

We're just a call away

Contact details

0

sales@qdchute.com

+86-133-5685-6582

+86-133-5685-6582